  velociti ? series mmi-10f gamewell-fci 12 clintonville road, northford, ct 06472 - tel: (203) 484-7161 - fax: (203) 484-7118 specifications are for information only, are not intended for installation purposes, and are subject to change without notice. no responsibility is assumed by gamewell-fci for their use. ?2006 gamewell-fci. all rights reserved. www.gamewell.fci.com 9020-0631 rev. b page 1 of 2 description the fci velociti ? series, multi-mod ten input monitor module (mmi-10f) provides ten (10), style b (class b) or five (5), style d (class a) supervised initiating device circuits (idcs) suitable for a wide range of monitoring applications. the velociti tm series use a communication protocol that substantially increases the speed of communication between the sensors and certain fci analog addressable fire alarm controls. these devices operate in a grouped fashion. if one of the devices in the group has a status change, the panel?s microprocessor stops the group poll and concentrates on the single device. the net effect is response speed up to five times greater than earlier designs. each supervised circuit may be connected to any normally open contact device such as manual stations, tamper and supervisory switches, waterflow switches, heat detectors, 4-wire smoke sensors, etc. the mmi-10f connects to the signaling line circuits (slc) of the fci analog addressable series fire alarm control panels. each of the mmi-10f circuits occupies its own address on the system?s slc allowing each to be fully programmable in its control-by-event sequence of operation. the address of the first circuit is set with a pair of rotary dials. each remaining circuit is automatically assigned to its own subsequent address. the mmi-10f module includes an address disable jumper matrix that allo ws a maximum of two unused addresses to be turned off to free these addresses for other purposes. an additional jumper setting selects either style b or style d circuit configurations. each circuit has its own status led that flashes to indicate proper polling and lights steadily when the output has been activated. velociti ? and e3 series ? are trademarks of fire control instruments. multi-mod ten input monitor module features ? each mmi-10f monitor module provides ten (10), style b (class b) or five (5), style d (class a) individually addressable, individually programmable initiating device circuits. ? ideal for applications requiring monitoring of normally open contact devices. ? removable wiring terminal blocks allow ease of installation and servicing. ? terminal blocks can accommodate 12 to 18 awg wire. ? flexible jumper configuration feature allowing one or two monitoring circuit addresses to be disabled. ? individual led indicators.* ? ideal for retrofit applications. ? as many as sixty (60), initiating device circuits in one (1), 12? x 24? x 6.5? cabinet. ? two (2), mounting cabinets available for two (2), (MBB-2 cabinet) to six (6), (mbb-6 cabinet) mmo-6rs. ? bicolor leds flash green whenever the sensor is addressed, and light steady red on alarm.* note: *only the red led is operative in panels that do not operate in velociti? mode. an iso 9001-2000 company mmi-10f
description (continued) two multi-mod units can be mounted in one MBB-2 cabinet. additional mounting options include the mch-6 chassis that can accommodate six (6), multi-mod modules. the mch-6 chassis can be installed in a custom cabinet or can be mounted in the mbb-6 cabinet allowing up to six (6), multi-mod modules in one cabinet. the mmi-10f is ideal for applications where centralized location of circuits is required. as many as sixty (60), initiating device circuits may be located in a cabinet that is only 12.6? h x 24? w x 6.5? d in dimension saving valuable wall space in mechanical rooms and electrical closets and reducing cost of installation. gamewell-fci 12 clintonville road, northford, ct 06472 - tel: (203) 484-7161 - fax: (203) 484-7118 www.gamewell.fci.com 9020-0631 rev. b page 2 of 2 specifications operating voltage: 15-32 vdc stand-by current: 3.5 ma alarm current: 60 ma (with all ten leds lit) maximum idc wire resistance: 40 ohms maximum idc voltage: 12 vdc maximum idc current: 1 ma temperature range: 32? f to 120 ? f (0 ? to 49 ? c) humidity 10 to 85% (non-condensing) dimensions: 6.8? h x 5.8? w x 1.25? d (17.3 x 14.7 x 3.2 cm) MBB-2 12.25? h x 9.25? w x 3.32? d (31.2 x 23.5 x 8.4 cm) mbb-6 12.63? h x 24? w x 6.5? d (32.1 x 60.1 x 16.5 cm) ordering information model description mmi-10f multi-mod 10 input module MBB-2 backbox, 2 unit mbb-6 backbox, 6 unit, requires mch-6 mch-6 6-unit mounting chassis


▲Up To Search▲   

 
Price & Availability of MBB-2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X